ALTRONIX AL400ULACM Access Power Controller w/ Power Supply/Charger

ALTRONIX AL400ULACM Access Power Controller w/ Power Supply/Charger


 

MSRP: (Members Only)

Quantity in Stock:2
Product Code: AL400ULACM
Qty:

Description
 
  • Input
    • Input 115VAC 60Hz rated @ 3.5.A
  • Power supply input options:
    • A) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
    • B) Two (2) isolated power inputs- One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (current is determined by the power supply connected, not to exceed a maximum of 10A total).
    • Eight (8) Access Control System trigger inputs.
  • Input options:
    • A) Eight (8) normally open (NO) inputs.
    • B) Eight (8) open collector inputs.
    • C) Any combination of the above.
  • Output
    • 12VDC or 24VDC outputs.
    • 12 VDC @ 4A supply current or 24VDC @ 3A supply current.
    • Class 2 Rated power limited outputs.
    • Eight (8) independently controlled outputs
  • Output options:
    • A) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
    • B) Eight (8) form "C" 5A rated relay outputs
    • C) Any combination of the above.
    • Eight (8) auxiliary power outputs (unstitched)
  • Output ratings:
    • Fuses are rated @ 3.5A.
    • Filtered and electronically regulated outputs (built-in power supply).
    • ACM8 board main fuse is rated at 10A
  • Supervison
    • AC fail supervison (form "C" contacts). Notification trigger is selectable for any or all of the eight (8) outputs.
    • Low battery and battery presence supervision (form "C" contact).
  • Features
    • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Fire Alarm disconnected input options:
    • A) Normally open (NO) or normally closed (NC) dry contacted input.
    • B) Polarity reversal indicates that FACP signaling circuit.
    • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
    • Short circuit and thermal over protection.
  • Visual Indicators
    • Red LEDs indicate outputs are triggered (relays energized).
    • Green LED indicates FACP disconnect is triggered.
    • AC input and DC output LED indicators.
  • Battery Backup
    • Built-in charger for sealed lead acid or gel type batteries.
    • Automatic switch over to stand-by battery when AC fails.
      • Zero voltage drop when unit switches over to battery backup (AC failure condition).
      • Battery fail and battery presence supervision (form "C" contact).
    • Temperature
      • Operating: 0° C to 49° C (32° F to 120°F).
      • Storage (-20° C to 70° C(-4°F to 158° F).
      • Relative Humidity 85% ± 5%
    • BTU/Hr. (approx.):
      • 12VDC: 25 BTU/Hr.
      • 24VDC: 37 BTU/Hr.